Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Biol Macromol ; 172: 580-588, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33476616

RESUMEN

Tissue adhesives have been developed for sealing tissue damaged in surgery. Among these, sheet-type adhesives require a relatively long time to adhere to biological tissue under wet conditions. To address this clinical problem, we fabricated a tissue-adhesive fiber sheet (AdFS) based on decanyl group (C10) modified Alaska pollock-derived gelatin (C10-ApGltn) using electrospinning. Ultraviolet (UV) irradiation of the AdFS was performed to increase the affinity between the AdFS and wet biological tissue by introducing hydrophilic functional groups. The UV irradiated AdFS (UV-C10-AdFS) strongly adhered to porcine pleura within 2 min under wet conditions and showed higher burst strength compared with the original ApGltn (Org-ApGltn) sheet. Hematoxylin-eosin stained sections revealed that a dense UV-C10-AdFS layer remained on the surface of the porcine pleura even after burst strength measurement. Moreover, UV-C10-AdFS has excellent cytocompatibility and efficiently supports the growth of L929 cells. UV-C10-AdFS is a promising adhesive material for sealing wet biological tissue.


Asunto(s)
Gelatina/química , Pleura/efectos de los fármacos , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Alaska , Animales , Línea Celular , Técnicas Electroquímicas , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Gadiformes/metabolismo , Gelatina/efectos de la radiación , Interacciones Hidrofóbicas e Hidrofílicas , Ensayo de Materiales , Ratones , Pleura/efectos de la radiación , Polietilenglicoles/química , Porcinos , Resistencia a la Tracción , Adhesivos Tisulares/farmacología , Rayos Ultravioleta
2.
ACS Appl Mater Interfaces ; 12(20): 22467-22478, 2020 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-32394696

RESUMEN

Current biomaterials and tissue engineering techniques have shown a promising efficacy on full-thickness articular cartilage defect repair in clinical practice. However, due to the difficulty of implanting biomaterials or tissue engineering constructs into a partial-thickness cartilage defect, it remains a challenge to provide a satisfactory cure in joint surface regeneration in the early and middle stages of osteoarthritis. In this study, we focused on a ready-to-use tissue-adhesive joint surface paint (JS-Paint) capable of promoting and enhancing articular surface cartilage regeneration. The JS-Paint is mainly composed of N-(2-aminoethyl)-4-(4-(hydroxymethyl)-2-methoxy-5-nitrosophenoxy) butanamide (NB)-coated silk fibroin microparticles and possess optimal cell adhesion, migration, and proliferation properties. NB-modified silk fibroin microparticles can directly adhere to the cartilage and form a smooth layer on the surface via the photogenerated aldehyde group of NB reacting with the -NH2 groups of the cartilage tissue. JS-Paint treatment showed a significant promotion of cartilage regeneration and restored the smooth joint surface at 6 weeks postsurgery in a rabbit model of a partial-thickness cartilage defect. These findings revealed that silk fibroin can be utilized to bring about a tissue-adhesive paint. Thus, the JS-Paint strategy has some great potential to enhance joint surface regeneration and revolutionize future therapeutics of early and middle stages of osteoarthritis joint ailments.


Asunto(s)
Cartílago Articular/fisiología , Fibroínas/química , Regeneración/efectos de los fármacos , Adhesivos Tisulares/química , Animales , Alcoholes Bencílicos/química , Alcoholes Bencílicos/efectos de la radiación , Alcoholes Bencílicos/toxicidad , Cartílago Articular/efectos de los fármacos , Adhesión Celular/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Fibroínas/toxicidad , Articulaciones/patología , Articulaciones/cirugía , Conejos , Adhesivos Tisulares/efectos de la radiación , Adhesivos Tisulares/toxicidad , Rayos Ultravioleta
3.
Nanoscale ; 12(16): 8679-8686, 2020 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-32253408

RESUMEN

Stimuli-responsive hydrogels with adaptable physical properties show great potential in the biomedical field. In particular, the collection of electrical signals is essential for precision medicine. Here, a simple strategy is demonstrated for achieving controlled drug release and real-time monitoring using an interpenetrating binary network consisting of a graphene aerogel and a poly(N-isopropylacrylamide) hydrogel with incorporated polydopamine nanoparticles (PDA-NPs). Owing to the good physical properties of graphene and the embedded PDA-NPs, the hybrid hydrogel shows enhanced mechanical properties and good electrical conductivity. In addition, the hybrid hydrogel also shows dual thermo- and near-infrared light responsiveness, as revealed by the controlled release of a model drug. In addition, as the hydrogel exhibits detectable changes in resistance during drug release, the drug-release behavior of the hydrogel can be monitored in real time using electrical signals. Moreover, owing to the abundance of catechol groups on the PDA-NPs, the hybrid hydrogel shows good tissue adhesiveness, as demonstrated using in vivo experiments. Thus, the developed hybrid hydrogel exhibits considerable practical applicability for drug delivery and precision medicine.


Asunto(s)
Preparaciones de Acción Retardada/química , Hidrogeles/química , Acrilamidas/química , Animales , Preparaciones de Acción Retardada/administración & dosificación , Preparaciones de Acción Retardada/farmacocinética , Preparaciones de Acción Retardada/efectos de la radiación , Sistemas de Liberación de Medicamentos , Conductividad Eléctrica , Grafito/química , Hidrogeles/administración & dosificación , Hidrogeles/farmacocinética , Hidrogeles/efectos de la radiación , Indoles/química , Rayos Infrarrojos , Ratones , Nanopartículas/química , Polímeros/química , Medicina de Precisión , Temperatura , Adhesivos Tisulares/administración & dosificación , Adhesivos Tisulares/química , Adhesivos Tisulares/farmacocinética , Adhesivos Tisulares/efectos de la radiación , Heridas y Lesiones/tratamiento farmacológico
4.
Biomacromolecules ; 21(1): 240-249, 2020 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-31596075

RESUMEN

Rapid adhesion between tissue and synthetic materials is relevant to accelerate wound healing and to facilitate the integration of implantable medical devices. Most frequently, tissue adhesives are applied as a gel or a liquid formulation. This manuscript presents an alternative approach to mediate adhesion between synthetic surfaces and tissue. The strategy presented here is based on the modification of the surface of interest with a thin polymer film that can be transformed on-demand, using UV-light as a trigger, from a nonadhesive into a reactive and tissue adhesive state. As a first proof-of-concept, the feasibility of two photoreactive, thin polymer film platforms has been explored. Both of these films, colloquially referred to as polymer brushes, have been prepared using surface-initiated atom transfer radical polymerization (SI-ATRP) of 2-hydroxyethyl methacrylate (HEMA). In the first part of this study, it is shown that direct UV-light irradiation of PHEMA brushes generates tissue-reactive aldehyde groups and facilitates adhesion to meniscus tissue. While this strategy is very straightforward from an experimental point of view, a main drawback is that the generation of the tissue reactive aldehyde groups uses the 250 nm wavelength region of the UV spectrum, which simultaneously leads to extensive photodegradation of the polymer brush. The second part of this report outlines the synthesis of PHEMA brushes that are modified with 4-[3-(trifluoromethyl)-3H-diazirin-3-yl]benzoic acid (TFMDA) moieties. UV-irradiation of the TFMDA containing brushes transforms the diazirine moieties into reactive carbenes that can insert into C-H, N-H, and O-H bonds and mediate the formation of covalent bonds between the brush surface and meniscus tissue. The advantage of the TFMDA-modified polymer brushes is that these can be activated with 365 nm wavelength UV light, which does not cause photodegradation of the polymer films. While the work presented in this manuscript has used silicon wafers and fused silica substrates as a first proof-of-concept, the versatility of SI-ATRP should enable the application of this strategy to a broad range of biomedically relevant surfaces.


Asunto(s)
Metacrilatos/química , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Animales , Azirinas , Benzoatos , Bovinos , Menisco/efectos de los fármacos , Menisco/efectos de la radiación , Metano/análogos & derivados , Metano/química , Procesos Fotoquímicos , Polimerizacion , Dióxido de Silicio/química , Propiedades de Superficie , Rayos Ultravioleta
5.
J Mater Chem B ; 7(42): 6488-6499, 2019 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-31576899

RESUMEN

Surgical sealants suitable for wounds with non-flat complex geometries are still a challenge to fulfill clinical requirements. Herein, a novel fit-to-shape sealant enhanced by photo-initiated crosslinking was developed utilizing maleic anhydride modified chitosan (MCS), benzaldehyde-terminated PEG (PEGDF) and polyethylene glycol diacrylate (PEGDA). Initially, the shear-thinning hydrogel prepared through the Schiff-base linkage between MCS and PEGDF could be injected into target sites, remolded to conform to a wound with non-flat complex geometry, and remain on the wound, avoiding adverse liquid leakage. Under illumination with ultra-violet (UV) light, the hydrogel was solidified in situ rapidly to adopt the wound contour and enhanced in adhesive strength to seal defects of the tissue. In addition, the hydrogel exhibits stability in extreme pH environments (pH = 1) and has potential to treat wounds inside the stomach with the existence of gastric acid. Moreover, the hydrogel can be applied as adhesive wound dressings through in situ 3D printing. Taken together, the fit-to-shape sealant enhanced by photo-initiated crosslinking can be considered as promising tissue adhesives for wound closure and other biomedical applications.


Asunto(s)
Hidrogeles/farmacología , Adhesivos Tisulares/farmacología , Cicatrización de Heridas/efectos de los fármacos , Animales , Línea Celular , Quitosano/análogos & derivados , Quitosano/farmacología , Quitosano/efectos de la radiación , Quitosano/toxicidad , Módulo de Elasticidad , Hidrogeles/química , Hidrogeles/efectos de la radiación , Hidrogeles/toxicidad , Ratones , Polietilenglicoles/química , Polietilenglicoles/farmacología , Polietilenglicoles/efectos de la radiación , Polietilenglicoles/toxicidad , Ratas , Porcinos , Resistencia a la Tracción , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Adhesivos Tisulares/toxicidad , Andamios del Tejido/química , Rayos Ultravioleta , Técnicas de Cierre de Heridas
6.
Biomacromolecules ; 18(3): 674-682, 2017 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-28124557

RESUMEN

The invasive practice of suturing for wound closure has persisted for millennia; with the rate of medical development, it is staggering that there are few viable alternatives to invasive mechanical fasteners. Biocompatible and biodegradable polymers are attractive candidates for versatile bioadhesives and could revolutionize surgical procedures. Bioadhesives can be broadly placed into two groups: activated and instant. Almost all commercially available bioadhesives are instant, which cross-link by mixing two components or on contact with moisture. Activated bioadhesives, on the other hand, allow control of when and where a bioadhesive cross-links and, in some cases, the extent of cross-linking. Despite significant progress, there has been little translation of activated bioadhesives to clinical use. This review discusses recent developments in UV-activated bioadhesives toward addressing unmet clinical needs.


Asunto(s)
Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Rayos Ultravioleta , Animales , Materiales Biocompatibles/química , Modelos Animales de Enfermedad , Humanos , Polímeros/química , Cicatrización de Heridas
7.
Mater Sci Eng C Mater Biol Appl ; 35: 300-6, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24411381

RESUMEN

In this study, a hybrid photopolymeric bioadhesive system consisting of urethane methacrylated dextran (Dex-U) and 3, 4-Dihydroxyphenyl-l-alanine (DOPA) modified three-arm poly (ethylene glycol) s (PEG-DOPAs) was designed. The process of photopolymerization was detected by Photo-Differential Scanning Calorimetry (Photo-DSC). The adhesion strength was evaluated by the lap shear tests. The surface tension of the solutions, burst pressures and the cytotoxicity assays were also investigated. The addition of PEG-DOPAs significantly improved the properties of Dex-U especially in the field of adhesion strength and burst pressure. And materials variation could be tailored to match the demands for tissue repair. Compared to the Dex-U systems, the maximum adhesion strength of the copolymeric system increased from 2.7±0.1 MPa to 4.0±0.6 MPa. Owing to its strong adhesion strength, rapid curing rate and good biocompatibility, such photocrosslinkable hydrogelsa could be applied to the areas of bioadhesive.


Asunto(s)
Materiales Biomiméticos/síntesis química , Dextranos/química , Polietilenglicoles/química , Adhesivos Tisulares/síntesis química , Adhesividad/efectos de la radiación , Reactivos de Enlaces Cruzados/síntesis química , Reactivos de Enlaces Cruzados/efectos de la radiación , Dextranos/efectos de la radiación , Dureza/efectos de la radiación , Luz , Ensayo de Materiales , Fotoquímica/métodos , Polietilenglicoles/efectos de la radiación , Adhesivos Tisulares/efectos de la radiación
8.
Photomed Laser Surg ; 26(3): 227-34, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18588436

RESUMEN

OBJECTIVE: The anastomosis of peripheral nerves is a demanding procedure that has potential complications due to foreign body reactions elicited by sutures. In this study, the sutureless in vivo anastomosis of rat tibial nerves was successfully performed, using for the first time a chitosan-based laser-activated adhesive. The nerve thermal damage caused by the laser irradiation was quantitatively assessed. MATERIALS AND METHODS: A novel adhesive composed of chitosan, indocyanine green, acetic acid, and water, was fabricated in thin sheets. Its adhesive strength was tested in vitro by bonding strips (surface area approximately 20 mm2, thickness approximately 20 microm) onto rat sciatic nerves and sheep intestine by laser activation with low fluence ( approximately 50 J/cm2), using a fiber-coupled diode laser (n = 13). The tensile strength of the adhesive/tissue bonds was measured after tissue repair. The chitosan adhesive was then used to perform sutureless anastomosis of tibial nerves in vivo (n = 6). Adhesive strips were also bonded in vivo onto intact rat sciatic nerves (n = 6) in order to quantitatively assess, by counting myelinated axons, the thermal damage induced by the laser. RESULTS: The adhesive bonded well to tissue with a tensile strength of 12.5 +/- 2.6 KPa (mean +/- SD; n = 13). The in vivo anastomosed nerves were in continuity 3 d after surgery. Axon counting showed the number and morphology of myelinated axons were normal proximally ( approximately 96%) compared with intact nerves (100%). Axon demyelination was observed at the operation site ( approximately 49%) and distally ( approximately 27%), and was attributed to laser-induced thermal damage. CONCLUSIONS: Nerve anastomosis, performed by the laser-adhesive procedure, was successful 3 d postoperatively. Proximal myelinated axons were not significantly damaged by the low laser fluence.


Asunto(s)
Quitosano/farmacología , Quitosano/efectos de la radiación , Rayos Láser , Nervios Periféricos/cirugía , Adhesivos Tisulares/farmacología , Adhesivos Tisulares/efectos de la radiación , Animales , Proyectos Piloto , Ratas , Nervio Ciático/fisiología , Ovinos , Resistencia a la Tracción
9.
Int J Pharm ; 352(1-2): 172-81, 2008 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-18065171

RESUMEN

Adhesives provide a needle-free method of wound closure and do not require local anaesthetics. Polymeric adhesives have been used for about 3 decades for joining several tissues of the organism. Also, they can accomplish other tasks, such as haemostasis and the ability to seal air leakages and have the potential to serve as delivery systems. PCL was modified with 2-isocyanatoethylmethacrylate to form a macromer that was crosslinked via UV irradiation using Irgacure 2959 by CIBA as the photoinitiating agent. The characterization of the materials was accomplished by: attenuated total reflectance-Fourier transform infrared (ATR-FTIR), swelling capacity determination, evaluation of adhesive capacity (by reaction with aminated substrates) and determination of surface energy by contact angle measurement. Thermal characterization of the adhesive was performed by dynamical mechanical thermal analysis (DMTA) and thermogravimetric analysis (TGA). The morphology of PCL networks was observed using scanning electron microscopy (SEM) both after crosslinking process and following biodegradation in human plasma. The haemocompatibility of the membranes was also evaluated by thrombosis and haemolysis tests.


Asunto(s)
Materiales Biocompatibles , Isocianatos/química , Metacrilatos/química , Poliésteres/química , Propano/análogos & derivados , Adhesivos Tisulares/química , Rayos Ultravioleta , Adhesividad , Animales , Biotransformación , Coagulación Sanguínea/efectos de los fármacos , Hemólisis/efectos de los fármacos , Humanos , Isocianatos/metabolismo , Isocianatos/farmacología , Isocianatos/efectos de la radiación , Ensayo de Materiales , Metacrilatos/metabolismo , Metacrilatos/farmacología , Metacrilatos/efectos de la radiación , Microscopía Electrónica de Rastreo , Fotoquímica , Poliésteres/metabolismo , Poliésteres/farmacología , Poliésteres/efectos de la radiación , Propano/química , Propano/efectos de la radiación , Conejos , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Termogravimetría , Factores de Tiempo , Adhesivos Tisulares/metabolismo , Adhesivos Tisulares/farmacología , Adhesivos Tisulares/efectos de la radiación , Agua/química
10.
Biomaterials ; 25(16): 3283-91, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-14980423

RESUMEN

Polyesterpolyol macromers were prepared with succinic acid and polyethylene glycols (PEG) of different molecular weights. The resulting polyols were acrylated to render them photo-cross-linkable. They could be very rapidly cross-linked into non-tacky films with long-wavelength UV radiation. The resulting products were characterized by gel content, water equilibrium swell, cross-link density, Tg , tensile strength, degradation and in vitro burst strengths. Though all of them formed transparent contact lens like films, increasing the PEG molecular weight has resulted in polymers with higher hydrophilicity resulting in higher swelling, faster degradation, higher tensile strength, elongation at break and burst strength. Addition of vinyl pyrrolidinone as a reactive diluent has increased the mechanical as well as burst strength of the polymer. In vitro release of sulfamethoxazole entrapped in these cross-linked matrices was also studied.


Asunto(s)
Acrilatos/química , Sistemas de Liberación de Medicamentos/métodos , Poliésteres/química , Polietilenglicoles/química , Sulfametoxazol/administración & dosificación , Sulfametoxazol/química , Adhesivos Tisulares/química , Acrilatos/efectos de la radiación , Animales , Materiales Biocompatibles/química , Materiales Biocompatibles/efectos de la radiación , Elasticidad , Dureza , Humanos , Ensayo de Materiales , Poliésteres/efectos de la radiación , Polímeros/química , Polímeros/efectos de la radiación , Resistencia a la Tracción , Adhesivos Tisulares/efectos de la radiación , Rayos Ultravioleta , Viscosidad , Agua/química , Cicatrización de Heridas/efectos de los fármacos , Cicatrización de Heridas/fisiología
11.
J Biomed Mater Res B Appl Biomater ; 66(1): 439-46, 2003 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-12808606

RESUMEN

A novel photocurable tissue adhesive glue, which is composed of styrene-derivatized (styrenated) gelatin, poly(ethylene glycol) diacrylate (PEGDA), and carboxylated camphorquinone in phosphate-buffered saline (PBS), was prepared. The prototype formulation suitable for arterial repair was determined based on the gel yield, degree of swelling, tissue adhesive strength, and breaking (or burst) strength in vitro. The formulated photocurable tissue adhesive glue with an appropriate viscosity was converted to a water-swollen gel within 1 min of visible light irradiation. The tissue adhesive glue, which was coated on a rat abdominal aorta incised with a pair of scissors, was immediately converted to a swollen gel upon subsequent irradiation with visible light, and concomitantly hemostasis was completed. Histological examination showed that the produced gel was tightly adhered to the artery shortly after photoirradiation. The gel gradually degraded with time and was completely absorbed within 4 weeks after treatment. These results indicate that the photocurable glue developed here may serve as a tissue adhesive glue applicable to vascular surgery.


Asunto(s)
Gelatina , Polietilenglicoles , Estireno , Adhesivos Tisulares/química , Animales , Aorta Abdominal/cirugía , Biodegradación Ambiental , Hemostasis Quirúrgica , Humanos , Técnicas In Vitro , Luz , Ensayo de Materiales , Ratas , Adhesivos Tisulares/metabolismo , Adhesivos Tisulares/efectos de la radiación
12.
Biomed Sci Instrum ; 39: 1-5, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12724859

RESUMEN

This study investigated the feasibility of bonding layers of porcine small intestinal submucosa (SIS, Cook Biotech, Inc.) with a light-activated protein solder. SIS is an acellular, collagen-based extracellular matrix material that is approximately 100 microns thick. The solder consists of bovine serum albumin and indocyanine green dye (ICG) in deionized water. The solder is activated by an 808 nm diode laser, which denatures the albumin, causing the albumin to bond with the collagen of the tissue. The predictable absorption and thermal energy diffusion rates of ICG increase the chances of reproducible results. To determine the optimal condition for laser soldering SIS, the following parameters were varied: albumin concentration (from 30-45% (w/v) in increments of 5%), the concentration of ICG (from 0.5-2.0 mg/ml H2O) and the irradiance of the laser (10-64 W/cm2). While many of the solder compositions and laser irradiance combinations resulted in no bonding, a solder composition of 45% albumin, ICG concentration of 0.5 mg/ml H2O, and a laser irradiance of 21 W/cm2 did produce a bond between two pieces of SIS. The average shear strength of this bond was 29.5 +/- 17.1 kPa (n = 14). This compares favorably to our previous work using fibrin glue as an adhesive, in which the average shear strength was 27 +/- 15.8 kPa (n = 40).


Asunto(s)
Mucosa Intestinal/química , Albúmina Sérica Bovina/química , Albúmina Sérica Bovina/efectos de la radiación , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Animales , Bovinos , Colágeno/química , Técnicas In Vitro , Verde de Indocianina/química , Verde de Indocianina/efectos de la radiación , Mucosa Intestinal/efectos de la radiación , Intestino Delgado/química , Intestino Delgado/efectos de la radiación , Rayos Láser , Luz , Presión , Desnaturalización Proteica , Sensibilidad y Especificidad , Resistencia al Corte , Estrés Mecánico , Porcinos , Soldadura/instrumentación , Soldadura/métodos
13.
Biomed Sci Instrum ; 39: 6-11, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12724860

RESUMEN

The feasibility of using alternative chromophores in laser tissue soldering applications was explored. Two commonly used chromophores, indocyanine green (ICG), and methylene blue (MB) were investigated, as well as three different food colorings: red #40 (RFC), blue #1 (BFC), and green consisting of yellow #5 and blue #1 (GFC). Three experimental studies were conducted: (i) The absorption profiles of the five chromophores, when diluted in deionized water and when bound to protein, were recorded; (ii) the effect of accumulated thermal dosages on the absorption profile of the chromophores was evaluated; and (iii) the stability of the absorption profiles of the chromophore-doped solutions when exposed to ambient light for extended time periods was measured. The peak absorption wavelengths of ICG, MB, RFC, and BFC, were found to be 805 nm, 665 nm, 503 nm, and 630 nm respectively in protein solder. The GFC had two absorption peaks at 426 nm and 630 nm, corresponding to the two dye components comprising this color. The peak absorption wavelength of ICG and MB was dependent on the choice of solvent (deionized water or protein). In contrast, the peak absorption wavelengths of the three chromophores were not dependent on the choice of solvent. ICG and MB showed a significant decrease in absorbance units with increased time and temperature when heated to temperature up to 100 degrees C. A significant decrease in the absorption peak occurred in the ICG and MB samples when exposed to ambient light for a period of 7 days. Negligible change in absorption with accumulated thermal dose up to 100 degrees C or light dose (over a period of 84 days) was observed for any of the three food colorings investigated.


Asunto(s)
Colorantes/química , Colorantes/efectos de la radiación , Rayos Láser , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Absorción , Animales , Bovinos , Estudios de Factibilidad , Colorantes de Alimentos/química , Colorantes de Alimentos/efectos de la radiación , Verde de Indocianina/química , Verde de Indocianina/efectos de la radiación , Luz , Ensayo de Materiales/métodos , Azul de Metileno/química , Azul de Metileno/efectos de la radiación , Desnaturalización Proteica , Radiometría/métodos , Sensibilidad y Especificidad , Albúmina Sérica Bovina/química , Albúmina Sérica Bovina/efectos de la radiación , Espectrofotometría/métodos , Soldadura/instrumentación , Soldadura/métodos
14.
Biomed Sci Instrum ; 39: 12-7, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12724861

RESUMEN

Clinical adoption of laser tissue welding (LTW) techniques has been beleaguered by problems associated with thermal damage of tissue and insufficient strength of the resulting tissue bond. The magnitude of these problems has been significantly reduced with the incorporation of indocyanine green (ICG)-doped protein solders into the LTW procedure to form a new technique known as laser tissue soldering (LTS). With the addition of ICG, a secondary concern has arisen relating to the potential harmful effects of the degradation products of the chromophore upon thermal denaturation of the protein solder with a laser. In this study, two different food colorings were investigated, including blue #1 and green consisting of yellow #5 and blue #1, as alternative chromophores for use in LTS techniques. Food coloring has been found to have a suitable stability and safety profile for enteral use when heated to temperatures above 200 degrees C; thus, it is a promising candidate chromophore for LTS which typically requires temperatures between 50 degrees C and 100 degrees C. Experimental investigations were conducted to test the tensile strength of ex vivo repairs formed using solders doped with these alternative chromophores in a bovine model. Two commonly used chromophores, ICG and methylene blue (MB), were investigated as a reference. In addition, the temperature rise, depth of thermal coagulation in the protein solder, and the extent of thermal damage in the surrounding tissue were measured. Temperature rise at the solder/tissue interface, and consequently the degree of solder coagulation and collateral tissue thermal damage, was directly related to the penetration depth of laser light in the protein solder. Variation of the chromophore concentration such that the laser light penetrated to a depth approximately equal to half the thickness of the solder resulted in uniform results between each group of chromophores investigated. Optimal tensile strength of repairs was achieved by optimizing laser and solder parameters to obtain a temperature of approximately 65 degrees C at the solder/tissue interface. The two alternative chromophores tested in this study show considerable promise for application in LTS techniques, with equivalent tensile strength to solders doped with ICG or MB, and the potential advantage of eliminating the risks associated with harmful byproducts.


Asunto(s)
Colorantes/química , Colorantes/efectos de la radiación , Rayos Láser , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Animales , Aorta Torácica/química , Aorta Torácica/efectos de la radiación , Bovinos , Colorantes de Alimentos/química , Colorantes de Alimentos/efectos de la radiación , Técnicas In Vitro , Verde de Indocianina/química , Verde de Indocianina/efectos de la radiación , Luz , Ensayo de Materiales/métodos , Azul de Metileno/química , Azul de Metileno/efectos de la radiación , Desnaturalización Proteica , Control de Calidad , Radiometría/métodos , Sensibilidad y Especificidad , Albúmina Sérica Bovina/química , Albúmina Sérica Bovina/efectos de la radiación , Espectrofotometría/métodos , Estrés Mecánico , Temperatura , Resistencia a la Tracción , Soldadura/instrumentación , Soldadura/métodos
15.
Biomed Sci Instrum ; 39: 18-23, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12724862

RESUMEN

The clinical acceptance of laser-tissue repair techniques is dependent on the reproducibility of viable repairs. Reproducibility is dependent on two factors: (i) the choice of materials to be used as the adhesive; and (ii) obtaining temperatures high enough to cause protein denaturation at the vital tissue interface without causing excessive thermal damage to the surrounding tissue. The use of a polymer scaffold as a carrier for the protein solder provides for uniform application of the solder to the tissue, thus allowing for pre-selection of optimal laser parameters. The scaffold also facilitates precise tissue alignment and ease of clinical application. In addition, the scaffold can be doped with various pharmaceuticals such as hemostatic and thrombogenic agents to aid wound healing. An ex vivo study was performed to correlate solder and tissue temperature with the tensile strength of arterial repairs formed using scaffold-enhanced light-activated surgical adhesives. Previous studies by our group using solid protein solder without the scaffold indicate that a solder/tissue, interface temperature of 65 degrees C is optimal. Using this parameter as a benchmark, laser irradiance was varied and temperatures were recorded at the surface and at the tissue interface of scaffold-enhanced protein solder using an infrared temperature monitoring system, designed by the researchers, and a type-K thermocouple, respectively.


Asunto(s)
Arteria Femoral/química , Arteria Femoral/efectos de la radiación , Verde de Indocianina/efectos de la radiación , Rayos Láser , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Animales , Relación Dosis-Respuesta en la Radiación , Arteria Femoral/lesiones , Arteria Femoral/patología , Técnicas In Vitro , Verde de Indocianina/química , Luz , Ensayo de Materiales/métodos , Desnaturalización Proteica , Control de Calidad , Sensibilidad y Especificidad , Albúmina Sérica/química , Albúmina Sérica/efectos de la radiación , Estrés Mecánico , Porcinos , Temperatura , Resistencia a la Tracción , Soldadura/instrumentación , Soldadura/métodos
16.
J Biomed Opt ; 6(1): 68-73, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11178582

RESUMEN

Newly developed light-activated surgical adhesives have been investigated as a substitute to traditional protein solders for vascular tissue fusion without the need for sutures. Canine femoral arteries (n = 14), femoral veins (n = 14), and carotid arteries (n = 10) were exposed, and a 0.3-0.6 cm longitudinal incision was made in the vessel walls. The surgical adhesive, composed of a poly(L-lactic-co-glycolic acid) scaffold doped with the traditional protein solder mix of bovine serum albumin and indocyanine green dye, was used to close the incisions in conjunction with an 805 nm diode laser. Blood flow was restored to the vessels immediately after the procedure and the incision sites were checked for patency. The new adhesives were flexible enough to be wrapped around the vessels while their solid nature avoided the problems associated with "runaway" of the less viscous liquid protein solders widely used by researchers. Assessment parameters included measurement of the ex vivo intraluminal bursting pressure 1-2 h after surgery, as well as histology. The acute intraluminal bursting pressures were significantly higher in the laser-solder group (>300 mmHg) compared to the suture control group (<150 mmHg) where four evenly spaced sutures were used to repair the vessel (n = 4). Histological analysis showed negligible evidence of collateral thermal damage to the underlying tissue in the laser-solder repair group. These initial results indicated that laser-assisted vascular repair using the new adhesives is safe, easy to perform, and contrary to conventional suturing, provides an immediate leak-free closure. In addition, the flexible and moldable nature of the new adhesives should allow them to be tailored to a wide range of tissue geometries, thus greatly improving the clinical applicability of laser-assisted tissue repair.


Asunto(s)
Luz , Adhesivos Tisulares/efectos de la radiación , Procedimientos Quirúrgicos Vasculares , Animales , Arterias Carótidas/patología , Arterias Carótidas/fisiopatología , Arterias Carótidas/cirugía , Perros , Arteria Femoral/patología , Arteria Femoral/fisiopatología , Arteria Femoral/cirugía , Vena Femoral/patología , Vena Femoral/fisiopatología , Vena Femoral/cirugía , Rayos Láser , Membranas Artificiales , Polímeros , Resistencia a la Tracción
17.
J Biomed Mater Res ; 48(4): 511-21, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10421695

RESUMEN

This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues photocured on rat liver surfaces were gradually degraded with time in vivo with infiltration of inflammatory cells and connective tissues without necrotic sign in surrounding tissue. In addition, in the laparoscopic surgery, percutaneous delivery of the glue and its in situ photogelation on rat liver surfaces were demonstrated using a specially designed fiberscope. These results indicate that the photocurable glues developed here may serve as a biodegradable tissue adhesive glue usable in cardiovascular surgery and endoscopic surgery.


Asunto(s)
Gelatina/química , Gelatina/efectos de la radiación , Polietilenglicoles/química , Polietilenglicoles/efectos de la radiación , Adhesivos Tisulares/química , Adhesivos Tisulares/efectos de la radiación , Anastomosis Quirúrgica/métodos , Animales , Aorta/lesiones , Aorta/cirugía , Perros , Hemostasis Quirúrgica/métodos , Humanos , Técnicas In Vitro , Hígado/lesiones , Hígado/cirugía , Ensayo de Materiales , Fotoquímica , Ratas , Resistencia a la Tracción
18.
Lasers Surg Med ; 23(5): 258-62, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9888321

RESUMEN

BACKGROUND/OBJECTIVE: Current albumin solders for tissue-welding are soluble in physiological fluids, prior to laser irradiation. These solders are therefore subjected to mechanical alterations, which can weaken the solder-tissue repair. In this study, an albumin solder (laser activated) was developed with low solubility and with the ability to retain (partially) its mechanical characteristics in saline solution. STUDY DESIGN/MATERIALS AND METHODS: Gauged protein samples of solder were immersed into 0.5 ml saline solution for fixed intervals of time. The solder samples contained four bovine serum albumin (BSA) concentrations: 56%, 66%, 70%, and 75% (by weight). A Bradford protein assay measured the BSA solubility of the solders. The 70% and 75% BSA solders were also used to weld in vitro Wistar rat intestine sections with a diode laser (lambda = 810 nm, power = 270 mW). RESULTS: The solubility of the 75% BSA solder was significantly decreased with respect to the other solders (Anova, P < 0.05). This solder also showed comparable weld strength (13 gm) to the 70% BSA solder. CONCLUSION: The 75% BSA solder strongly reduced the albumin solubility in saline solution, without affecting its tissue-welding properties.


Asunto(s)
Terapia por Láser , Albúmina Sérica Bovina/química , Adhesivos Tisulares/química , Análisis de Varianza , Animales , Bovinos , Relación Dosis-Respuesta a Droga , Evaluación Preclínica de Medicamentos , Indicadores y Reactivos , Intestinos/cirugía , Terapia por Láser/métodos , Modelos Lineales , Ratas , Ratas Wistar , Albúmina Sérica Bovina/análisis , Albúmina Sérica Bovina/efectos de la radiación , Albúmina Sérica Bovina/uso terapéutico , Solubilidad/efectos de la radiación , Adhesivos Tisulares/análisis , Adhesivos Tisulares/efectos de la radiación , Adhesivos Tisulares/uso terapéutico
19.
ASAIO J ; 41(3): M374-8, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-8573828

RESUMEN

In this article, the authors present a novel photochemically driven hemostatic technology using photocurable gelatins partially derivatized with photoreactive xanthene dyes (fluorescein, eosin, and rose bengal) and a hydrophilic difunctional macromer. The developed hemostatic glue consisted of dye derivatized gelatin (20 wt%), poly(ethylene glycol) diacrylate (10 wt%), and ascorbid acid (0.3 wt%), all of which were dissolved in a saline solution. Irradiation of the hemostatic glue by visible light produced a swollen gel within a few tenths of a second due to dye sensitized photo-crosslinking and photograft polymerization. An increase in irradiation time resulted in an increased gel yield and reduced water swellability. A rat liver injured on laparotomy was coated with the hemostatic glue. Upon visible light irradiation through an optical fiber, the coated viscous solution was immediately converted to a swollen gel and, concomitantly, hemostasis was completed. Histologic examination showed that, at 7 days after surgery, little gelatin remained in the injured region, scarring with little necrosis occurred, and inflammatory cells infiltrated from the surrounding tissue and tissue regeneration proceeded well. During laparoscopic surgery, in situ gelation of the hemostatic glue on the liver surface was demonstrated using a specially designed fiberscope.


Asunto(s)
Gelatina , Técnicas Hemostáticas , Animales , Colorantes , Estudios de Evaluación como Asunto , Gelatina/efectos de la radiación , Laparoscopios , Hígado/lesiones , Fotoquímica , Ratas , Ratas Wistar , Adhesivos Tisulares/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...